Fisher & Paykel Freezer Code 11: Heater and Fan Current Low
Fault 11: one reading for heater and both fans, too low. Wait out the 20-second test before reading.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 11 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The measured current of the ambient heater, PC fan and FC fan is lower than it should be.
Fault 11 names a trio rather than a single part. The power module measures what the LAH heater and the two fans (PC for fresh food, FC for the freezer) draw as a group, and here that draw is under the expected level.
At a glance
| Code | 11 |
|---|---|
| What it means | The measured current of the ambient heater, PC fan and FC fan is lower than it should be. |
| What you can check | Wait the full 20 seconds with the doors shut after power-up before noting the code. Quiet the alarm with a control button or unplug the unit for a few seconds, and leave the connector untouched. |
| When to call a technician | A technician has to check the fan and heater connector at the power module and replace the module if needed. Say whether the alarm began just after power-up or a door closing. |
Abbreviations
| Short form | Stands for |
|---|---|
| LAH | low ambient heater |
| PC fan | fan on the fresh food side |
| FC fan | fan on the freezer side |
One 6-way fan/LAH RAST connector serves all three, so a single loose plug may show the identical code for each.
Be careful when you read it
Whenever the refrigerator gets power at the supply, or a door shuts while it is live, a test run of 20 seconds begins, and an open door interrupts it. The manual’s example: leave the heater and fan connector off, open a door when the alarm starts, and the display shows 13, because the heater comes first in the order of tests. If the doors stay shut until the end, it shows 11. The manual therefore advises technicians to wait the 20 seconds first, and anyone writing down a code should do the same.
Service procedure
- Check the 6-way fan/LAH RAST connector at the power module.
- If the code persists, reterminate that connector.
- Replace the power module as the very last step.
Meanwhile
Quiet the alarm using a control button, or unplug the unit for a few seconds. The connector should stay untouched, as it is found at the power module.
Related codes
- Code 12: same loads, current too high.
- Code 13: heater only, low current.
- Code 15: PC fan only, low current.
Refrigerator service across the metro areas
Fisher & Paykel Active Smart refrigerators are serviced in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Call (844) 659-2290 and describe whether the alarm began just after power-up or a door closing. Details: refrigerator repair.
Source: Fisher & Paykel Active Smart Refrigerators service manual 517775 (2004), Fault Code Display Status