Fisher & Paykel Freezer Code 13: Low Ambient Heater
Fault 13: low ambient heater current is below expectation. Check wiring, then measure the heater.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 13 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The low ambient heater is drawing less current than expected because of an open circuit or a faulty heater.
Fault 13 reports on the low ambient heater (LAH). Each time the power module energises it, a certain current is anticipated, and here the reading comes in low. The service manual blames an open circuit somewhere in the heater or its wiring, or a defective heater.
At a glance
| Code | 13 |
|---|---|
| What it means | The low ambient heater is drawing less current than expected because of an open circuit or a faulty heater. |
| What you can check | Press any control button to quiet the alarm, or unplug for a few seconds to reset it. Leave the wiring alone rather than probing it, and note whether doors were opened as the alarm went off. |
| When to call a technician | A technician must check the heater wiring and connections and the heater itself. Mention if a door was opened during the 20-second test, since that can show an early result. |
Open circuit, simply put
The path is broken, so current cannot get through. A plug that has come loose, a wire that has snapped or an element that has burnt out would look identical to the module.
What service checks
- All wiring and connections, at the heater as well as at the power module.
- The ambient heater’s resistance. Out-of-limits means the heater is swapped.
Nothing beyond that is given, and the limits do not appear in this part of the manual.
Why the number shown may not be final
The heater leads the order of the 20-second self-test. Disconnect the fan and heater connector at the power module, then open a door the instant the alarm sounds, and code 13 results because testing never moved beyond item one. Technicians let the whole 20 seconds go by before opening the door, so they see the correct final code. Thus, an alarm at power-up followed by a quick door opening can leave you holding an early test result.
Practical tips
- Any control button quiets the alarm; unplugging for a few seconds resets it.
- Leave the wiring alone rather than probing it.
- Tell service whether doors were opened as the alarm went off.
Compare
- Code 14: the same heater, drawing excess current
- Code 11: heater and both fans, insufficient current together
Heater service, metro areas
For a Fisher & Paykel refrigerator heater fault around Miami, New York, Houston, Los Angeles or San Diego, dial (844) 659-2290. Have the code ready and recall whether the door was opened during the alarm. Read about refrigerator repair if you want the scope.
Source: Fisher & Paykel Active Smart Refrigerators service manual 517775 (2004), Fault Code Display Status