Fisher & Paykel Washer Code 108: Coms CRC Error, Phase 6 IW
Code 108 is a CRC communications error that the Fisher & Paykel manual limits to Phase 6 IW displays and answers with a pointer to fault 106.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 108 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
Coms CRC error listed for the Phase 6 IW display only; the manual says to see fault code 106.
In the manual, 108 occupies one line. It names a “Coms CRC error”, limits it to Phase 6 IW displays, and refers on to fault code 106.
At a glance
| Code | 108 |
|---|---|
| What it means | A communications data-corruption error between the display and controller on one Phase 6 display type only. |
| What you can check | Note the number shown, the model name, and any module replaced earlier. Do not try other modules in the console. |
| When to call a technician | Bring in a technician, who will follow the display and controller module procedure, replacing the display first. Mismatched modules can stop the machine, so mention any earlier part changes. |
Scope of the code
- Only the Intuitive (IW) display of Phase 6 machines is concerned.
- Models listed for it: IW811, IW711, IW511, IWL11, IWM11, MWC11.
- A 108 from some other model cannot be confirmed.
What a CRC error is
CRC stands for cyclic redundancy check, a method by which an electronic device verifies that a received message was not corrupted. Applied here, it means the data passing between Display and Motor Controller was corrupted or did not tally. Past the label, the manual says nothing.
What 106 contains
| Source | Action |
|---|---|
| Display module (primary) | Replace |
| Motor Controller module (secondary) | Replace; if the new one fixes the fault, put the original Display back |
Details for the phone call
The written information is thin, which makes the call important. Report the number displayed and the model name, and mention any module replaced earlier. The manual cautions that an IW can end up with an unsuitable Motor Controller.
Related entries
Intuitive washer service in our metro areas
Service covers the Miami, New York, Houston, Los Angeles and San Diego metro areas. Ring (844) 659-2290 to book.
Source: Fisher & Paykel Phase 6 Series 11 (GWL11) service manual 517766, Detailed Fault Codes