Fisher & Paykel Refrigerator Code 11: Heater and Fan Current Low
The heater, PC fan and FC fan draw less current than expected together; the manual starts at their shared connector.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 11 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The current measured for the ambient heater, PC fan and FC fan is lower than expected.
Code 11 bundles together the low ambient heater, the PC fan and the FC fan, whose currents the power module adds up. That total was too low.
At a glance
| Code | 11 |
|---|---|
| What it means | The current measured for the ambient heater, PC fan and FC fan is lower than expected. |
| What you can check | Keep the doors shut and wait the full 20 seconds of start-up tests before reading the code. A button, or a brief loss of power, quiets the alarm. Do not open the back of the cabinet. |
| When to call a technician | If code 11 survives the start-up test, book a service visit. A technician needs to inspect and remake the connector at the power module, and may replace the module. |
What the three parts share
A single 6-way connector, named the fan/LAH RAST connector in the manual, plugs each of them into the power module. The manual’s order for the code reads:
- Inspect the connector on the module.
- Reterminate it.
- If the code will not clear, fit a new power module.
A loose or disconnected connector carries nothing, so a low figure is no surprise.
Why it can appear right after power-on
- A 20-second series of tests begins when the fridge is switched on at the supply or a door closes mid-run.
- First to be tested is the low ambient heater.
- Doors kept shut to the end of the tests: an unplugged fan/heater connector gives code 11.
- A door opened the moment the alarm goes off: the tests stop part-way, and code 13 may appear in its place.
- Wait for all 20 seconds, says the manual, then read the code.
For the household
The manual gives owners no repair here. A button, or a brief loss of power, quiets the alarm. Looking at a connector means opening the back of the cabinet, which a trained technician should do.
Related fault codes
- Code 12: those three again, with current above the mark.
- Code 13: just the heater, below the mark.
- Code 15: just the PC fan, below the mark.
Refrigerator repair in Miami, New York, Houston, Los Angeles and San Diego
Repair visits for Fisher & Paykel refrigerators cover the Miami, New York, Houston, Los Angeles and San Diego metro areas. If code 11 survives the start-up test, call (844) 659-2290 and note whether the fridge was recently moved or serviced. See the refrigerator repair page for more.
Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
Tell us what’s wrong — we’ll take it from there
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.