Fisher & Paykel Freezer Code 3: Every Sensor Out of Range
Fault 3: the control sees all temperature sensors above the normal resistance range.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 3 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
Resistance of all the temperature sensors is outside normal, above 45K ohms.
Instead of blaming one sensor, fault 3 reports a reading above 45K ohms from every temperature sensor, which is beyond normal. The manual’s actions are aimed at the connector they share and at the power module.
At a glance
| Code | 3 |
|---|---|
| What it means | Resistance of all the temperature sensors is outside normal, above 45K ohms. |
| What you can check | Press a button to quiet the alarm and write down the flashing LED pattern. The connector sits on the power module, so there is nothing further for you to check. |
| When to call a technician | A technician needs to inspect the shared connector at the power module and may need to replace the module. Say whether the unit still cools when you call. |
What 45K means
The manual includes a thermistor table. A sensor should give around 25.17K ohms at -30 degrees C and about 0.9106K ohms at 50 degrees C, with resistance falling as it gets warmer. Anything over 45K is off the cold end of that table, nowhere near the value of a healthy kitchen freezer sensor.
Action list
| Rank | What to do |
|---|---|
| Primary | Look over the 6 way RAST connector where it meets the power module |
| Secondary | Reterminate it |
| Tertiary | Install a new power module |
That is the order printed in the manual.
Not for owners to repair
The power module carries the connector, so a technician should handle it. Your job is limited to quieting the alarm with a button press and writing down the flashing LED pattern.
Related codes
- Code 4: also all sensors, yet under 660 ohms
- Code 1: power module self-test failure at the previous power-up
- Code 9: only the PC sensor reads high
Freezer service in the metro areas
Freezer service for Fisher & Paykel units reaches the Miami, New York, Houston, Los Angeles and San Diego metro areas. Call (844) 659-2290 and give code 3 with the model number; saying whether the unit still cools helps. See refrigerator repair.
Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775, sections 1.0 and 2.0
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
Tell us what’s wrong — we’ll take it from there
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.