Fisher & Paykel Freezer Code 4: All Temperature Sensors Low
Fault 4 means the control sees every temperature sensor under the normal resistance range.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 4 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
All temperature sensors measure outside the normal resistance range, below 660 ohms.
If the freezer flashes 4, the control is complaining about all of its temperature sensors together: each one measures below 660 ohms, which is out of range. It is the low counterpart of code 3.
At a glance
| Code | 4 |
|---|---|
| What it means | All temperature sensors measure outside the normal resistance range, below 660 ohms. |
| What you can check | Press a button to quiet the alarm or take the power away for a few seconds, and note which LEDs are lit. After a fresh switch-on or door closing, allow 20 seconds with doors closed before trusting the code. |
| When to call a technician | A technician must check and possibly reterminate the connector at the power module, or replace the module. Mention anything else on the appliance that misbehaves. |
Where 660 ohms sits
The manual’s thermistor table runs down to 0.9106K ohms at 50 degrees C, about 910 ohms. A figure under 660 ohms is lower than even that warmest row. The same table lists 2.186K ohms for 25 degrees C.
Checks the manual lists, in rank order
| Rank | Step |
|---|---|
| Primary | Look over the 6 way RAST connector at the power module |
| Secondary | Reterminate the 6 way RAST connector |
| Tertiary | Replace the power module |
Since all the sensors are involved, none of these steps targets an individual sensor.
Owner actions
Not many. Press a button to quiet the alarm, or take the power away for a few seconds, and note which LEDs are lit. The rest is work for a technician. If the freezer was only just switched on or a door was only just closed, allow 20 seconds with the doors closed for the self-test before trusting what you see.
See also
- Code 3 covers all sensors reading too high.
- Code 6 is the freezer (FC) sensor alone reading too low.
Freezer repair in our metro areas
We handle Fisher & Paykel freezer calls in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Phone (844) 659-2290 with code 4 and your model number, and mention what else on the appliance misbehaves. Our refrigerator repair page has the general details.
Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775, sections 1.0 and 2.0