Code 49 flags the cold valve alone. The manual refers to the code 48 steps and points to its harness or an open circuit.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 49 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The valve diagnostic circuit indicates the cold (proportional) valve is faulty, most likely from its harness or an open circuit.
The cold valve alone
This code limits the valve problem to the cold side. The Motor Controller measured a voltage that, on the valve diagnostic circuit, points to a faulty cold valve (the proportional valve, in the manual’s terms). Phases 2 to 6 can show it.
At a glance
| Code | 49 |
|---|---|
| What it means | The valve diagnostic circuit indicates the cold (proportional) valve is faulty, most likely from its harness or an open circuit. |
| What you can check | Owners can only note the code and the washer model here. |
| When to call a technician | A technician needs to check the cold valve harness and coil, which needs access inside the machine and a meter. Give the code and model. |
Where the steps are
Under 49 the manual names the procedure for fault code 48 as the one to follow, and gives the identical likely cause: the valve harness not correctly connected, or an open circuit valve.
- Check the harness is secured to the valve and the pins are not bent backwards.
- Check the valve coil for open circuit.
- As a last resort, replace the Motor Controller module.
Reading 49 in diagnostic mode
The manual picks this code to demonstrate how the last fault is read. Diagnostic mode shows the binary code on the Wash Progress lights; adding 32 + 16 + 1 gives 49, identified as a cold water valve fault. The button sequence for the model has to be used to enter diagnostic mode, so treat this as technician-level.
Specification table (Series 11)
| Item | Value |
|---|---|
| Resistance, proportional valve | 64 ohms at 20 C (68 F) |
| Flow rate | 16 litres per minute |
| Supply voltage | 24 volts DC |
Coil orientation
The Series 11 notes say that a valve may be supplied with its coil in either of two orientations while the fittings stay identical. A small retaining clip must be released before the harness plug will come off.
Neighbouring codes
Code 48 takes in both valves, whereas code 50 is the hot side.
Cold-valve service in the covered metro areas
The number for Miami, New York, Houston, Los Angeles and San Diego area washer service is (844) 659-2290. Give the code and washer model.
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
Tell us what’s wrong — we’ll take it from there
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.