Code 50 points at the hot (digital) valve. The manual adds that Phase 5 can show 50 without any fault after a power-off during spin.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 50 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The valve diagnostic circuit voltage indicates the hot (digital) valve is faulty, most likely from its harness or an open circuit.
The three valve codes line up as 48 (both), 49 (cold) and 50 (hot). Code 50 is the hot one: a voltage on the valve diagnostic circuit, as measured by the Motor Controller, indicates that the hot valve, which the manual names the digital valve, is faulty. It applies to Phases 2 to 6.
At a glance
| Code | 50 |
|---|---|
| What it means | The valve diagnostic circuit voltage indicates the hot (digital) valve is faulty, most likely from its harness or an open circuit. |
| What you can check | If the washer was switched off while it was spinning, the code can show without any real fault. Otherwise, only an owner can notice whether power was cut mid-spin; the valve wiring itself is for a technician. |
| When to call a technician | Book a service visit if code 50 appears when the power was not interrupted. A hot valve with a wrongly connected harness or an open coil needs the washer opened up and tested. |
A Phase 5 warning
A separate statement in the manual says Phase 5 can produce fault code 50 when the Smartdrive is switched off while spinning, and that no fault exists in that case. After an interrupted spin, a 50 on a Phase 5 washer does not show a valve problem by itself.
Real fault: what to check
- The valve harness is correctly connected and its pins are not bent backwards.
- The valve coil is not open circuit.
- The Motor Controller module comes last.
These are taken from the fault code 48 procedure. As the likeliest cause, the manual gives a valve harness that is connected incorrectly, or an open circuit valve.
Specification detail
| Item | Manual statement |
|---|---|
| Low flow | May affect the digital (hot) valve, with seating problems for the seal |
| Operating pressure | From 20 kPa (3 PSI) at the low end to 1034 kPa (150 PSI) at the high end |
No direct link to code 50 is drawn in the manual; read the figures as background.
Compare
Code 48 covers both valves and code 49 covers the cold valve alone.
Hot valve service for the metro areas
To report a hot water valve code in Miami, New York, Houston, Los Angeles or San Diego, use (844) 659-2290. Mention it if power was cut during a spin.
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
Tell us what’s wrong — we’ll take it from there
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.