Fisher & Paykel Refrigerator Code 3: All Temperature Sensors High

Error code 3
Appliance Refrigerator
Quick answer

All temperature sensors read above 45K ohms together, so the manual looks at their common connector first.

Model compatibility: Fisher & Paykel reuses codes across series and model years, so 3 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.

Plain language

What this code means

The resistance of all the temperature sensors is outside the normal range, above 45K ohms.

Usually a sensor code points at one sensor. Code 3 does not, because all of the refrigerator’s temperature sensors read over 45K ohms together.

At a glance

Code 3
What it means The resistance of all the temperature sensors is outside the normal range, above 45K ohms.
What you can check Hush the alarm with a button and reset it with a short power cut. Keep watch on the food for warming or freezing, and move delicate items elsewhere if needed.
When to call a technician Access to the power module and its connector is for technicians only, who may remake the connections or replace the module. Book a service visit if the code shows after the power cut.

Common connector, three steps

One 6-way RAST connector carries all the sensors into the power module, so the manual starts there.

  1. Look at that RAST connector on the module.
  2. Make the terminations again.
  3. Still showing? Replace the module.

An unplugged or open sensor circuit gives the control a resistance this high.

Normal values for comparison

  • Near 6 kilohms when it is 0 degrees C.
  • 2.186 kilohms when it is 25 degrees C.
  • Only 25.17 kilohms at the very cold minus 30 degrees C.
  • Tolerance in the table: 5 percent.

A value beyond 45 kilohms exceeds every entry, so it is not a genuine temperature.

Owner role

Quite small. Access to the power module and its connector is for technicians alone. Hush the alarm with a button, reset it with a short power cut, and keep watch on the food. Regulation suffers without sensor readings, so check for it warming up or freezing and shift delicate food elsewhere if necessary.

See also

  • Code 4: all sensors low instead, below 660 ohms.
  • Code 9: the fresh food sensor alone, over the limit.

Fisher & Paykel refrigerator service in Miami, New York, Houston, Los Angeles and San Diego

Call (844) 659-2290 about code 3 for service in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Have the model number to hand and mention any recent move or unplugging. See the refrigerator repair page as well.

Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775

Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

References

Sources & references

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area Serving Miami, New York, Houston, Los Angeles and San Diego metro areas.
Response time Same-day and next-day appointments in most areas.
Call Book diagnosis