Fisher & Paykel Freezer Code 5: FC Sensor Resistance High

Error code 5
Appliance Freezer
Quick answer

Fault 5 means the freezer (FC) sensor resistance has gone over the normal range.

Model compatibility: Fisher & Paykel reuses codes across series and model years, so 5 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.

Plain language

What this code means

The FC (freezer) sensor resistance is outside the normal range, over 45K ohms.

What 5 reports

Fault 5 concerns the FC sensor, the freezer compartment’s temperature sensor. The control reads its resistance as more than 45K ohms, which is outside the normal range. Code 3 covers all sensors at once, so this one is the narrower fault.

At a glance

Code 5
What it means The FC (freezer) sensor resistance is outside the normal range, over 45K ohms.
What you can check Nothing here is for the owner to do. The sensor diagnostic display is meant for service work and should be used only on instruction.
When to call a technician A technician will look at the sensor connection at the power module and replace the sensor if the connection is fine. Give the code and model number when booking.

Thermistor background

A thermistor changes resistance with temperature. In the service manual’s table the sensor is 25.17K ohms at -30 degrees C and 6.000K ohms at 0 degrees C. Over 45K is past the top of that table.

What the manual has the technician do

First, look at the sensor connection at the power module. If it is in good order, the sensor gets replaced.

Seeing the temperature on the unit

A technician can hold MODE and press the temperature UP button to start a diagnostic mode. The display begins with the PC sensor temperature, and one more UP press brings up the FC sensor. To get the temperature, add together the values of the LEDs that are lit and take away 40. The mode quits after 5 minutes if nobody exits it, and door alarms are off while it is active. It is meant for service work, so use it only on instruction.

Sibling codes

  • Code 6 is the same FC sensor with resistance below range.
  • Code 9 is the PC (fresh food) sensor above range.
  • Code 3 is the all-sensor fault above range.

Where we repair freezers

Our Fisher & Paykel freezer service covers the Miami, New York, Houston, Los Angeles and San Diego metro areas. Call (844) 659-2290 and give the code and model number of the unit. See the refrigerator repair page too.

Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775, sections 1.0 and 2.0

Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

References

Sources & references

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area Serving Miami, New York, Houston, Los Angeles and San Diego metro areas.
Response time Same-day and next-day appointments in most areas.
Call Book diagnosis