Skip to content
Same-day and next-day appointments in most areas.
Specialized Fisher & Paykel repair service. Experienced technicians, genuine parts, service across major U.S. metro areas.
Error Code

Fisher & Paykel Freezer Code 2: Two Defrosts Aborted

Error code 2
Appliance Freezer
Quick answer

Fault 2 reports two aborted defrosts in a row on Active Smart units.

Model compatibility: Fisher & Paykel reuses codes across series and model years, so 2 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.

Plain language

What this code means

The two most recent defrosts were aborted after 30 minutes each.

Defrosting is the subject of fault 2. The Fisher & Paykel service manual says it shows when the previous two defrosts were aborted after 30 minutes. Two in a row means a recurring problem, not a one-off.

At a glance

Code 2
What it means The two most recent defrosts were aborted after 30 minutes each.
What you can check Silence the alarm with any button, knowing the fault pattern returns after 8 seconds of normal display. Switch off power for several seconds to reset it. Do not chip ice or use a hair dryer or knife.
When to call a technician Call a technician, since testing the defrost heater means opening the cabinet near live wiring. Say when the alarm first began and whether it has been sounding since.

At a glance

Item Detail
Meaning Last two defrosts aborted after 30 minutes
Manual’s action Check the defrost heater assembly in the FC; replace if faulty
Reference Fault-finding flow chart for the D1 defrost heater

The manual gives no further cause. A defrost heater warms the freezer-side evaporator so frost melts away. Testing it requires opening the cabinet near live wiring, which is not owner work, so the defrost system is for a technician to deal with.

Observations worth making

  1. Make a note of the display, the LEDs and the time the alarm started.
  2. Silence the alarm with any button; the fault pattern returns once 8 seconds of normal display have passed.
  3. Switch off power for several seconds to reset the alarm, or wait 72 hours for it to reset itself.

Leave ice alone: no chipping, no hair dryer, no knife.

Possibly related sensor codes

  • Code 7, evaporator sensor reading too high
  • Code 8, evaporator sensor reading too low
  • Code 5, FC sensor reading too high

What the repeat means

Because the code only appears after two defrosts in succession have ended early, a single odd defrost does not produce it. When you describe the situation on the phone, say when the alarm first began and whether it has been sounding since.

Defrost service in the metro areas

Defrost faults on Fisher & Paykel units are handled around Miami, New York, Houston, Los Angeles and San Diego. Call (844) 659-2290 with the model number and say how long the code 2 alarm has been going. Details are on the refrigerator repair page.

Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775, section 1.0

Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

References

Sources & references

Code still active?

Have this Fisher & Paykel alert verified on site

Repeating fault codes usually need platform-specific testing. We confirm the cause and price the fix before work begins.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area Serving Miami, New York, Houston, Los Angeles and San Diego metro areas.
Response time Same-day and next-day appointments in most areas.
Call Book diagnosis