Fault 7 flags the evaporator sensor with resistance above the normal range.
Model compatibility: Fisher & Paykel reuses codes across series and model years, so 7 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The evaporator sensor resistance is outside the normal range, over 45K ohms.
What 7 refers to
The evaporator sensor is behind fault 7; its resistance has climbed past 45K ohms. In a refrigerator or freezer the evaporator is the cold coil that chills the air.
At a glance
| Code | 7 |
|---|---|
| What it means | The evaporator sensor resistance is outside the normal range, over 45K ohms. |
| What you can check | This one has no owner fix. Jot down the code and LED pattern, whether the alarm was silenced or power disconnected, and wait out the 20-second self-test before relying on the code. |
| When to call a technician | A technician will check the connection at the power module and replace the evaporator sensor if it is fine. Say whether the fault came after switching on or after a door was closed. |
Instructions in the manual
Technicians start by checking the connection at the power module. If that is fine, they replace the evaporator sensor.
Reading the number
Thermistor resistance changes with temperature. The manual’s table lists a few thousand ohms across ordinary temperatures, such as 6.000K ohms at 0 degrees C, so more than 45K is far out of bounds. That is why the control raises a fault rather than treating it as a cold reading.
Place in the sensor family
The manual pairs each sensor with a high-resistance code and a low-resistance code. The evaporator sensor uses 7 for high and 8 for low. The FC sensor has 5 and 6, and the PC sensor has 9 and 10.
Before the technician arrives
Jot down the following to save time at the first visit:
- The code, plus the LED pattern, as the code is displayed in binary.
- If the alarm was silenced, and if the power was disconnected to silence it.
- Whether the fault came straight after switching on or after a door was closed.
The reason is the 20-second self-test at power-up and door closing. The manual says to wait out that sequence before relying on the code.
Freezer repair, metro areas
Customers in the Miami, New York, Houston, Los Angeles and San Diego metro areas can reach us on (844) 659-2290. See the refrigerator repair page as well.
Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775, sections 1.0 and 2.0